Showing 1–9 of 11 results

  • S3 – 3.75

    0.00

    Overdenture ball-attachments.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M201)
    2mm (Ref: M202)
    3mm (Ref: M203)
    4mm (Ref: M204)
    5mm (Ref: M205)
    6mm (Ref: M206)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts* Metal cap (Ref: C21)
    Hard silicone (Ref: C22)
    Standard silicone (Ref: C23)
    Soft silicone (Ref: C24)

    *The package contains only the metal cap and the standard silicone.

  • S3 – S7 – 3.75, 17°

    0.00

    Angular overdenture ball-attachments 17°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32171/C4205)
    2mm (Ref: M32172/C4205)
    3mm (Ref: M32173/C4205)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts* Metal cap (Ref: C21)
    Hard silicone (Ref: C22)
    Standard silicone (Ref: C23)
    Soft silicone (Ref: C24)

    *The package contains only the metal cap and the standard silicone.

  • S3 – S7 – 3.75, 30°

    0.00

    Angular overdenture ball-attachments 30°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32301/C4205)
    2mm (Ref: M32302/C4205)
    3mm (Ref: M32303/C4205)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts* Metal cap (Ref: C21)
    Hard silicone (Ref: C22)
    Standard silicone (Ref: C23)
    Soft silicone (Ref: C24)

    *The package contains only the metal cap and the standard silicone.

  • S35 – 3.75

    0.00

    Overdenture S-Lock abutments.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M1121)
    2mm (Ref: M1122)
    3mm (Ref: M1123)
    4mm (Ref: M1124)
    5mm (Ref: M1125)
    6mm (Ref: M1126)
    Instructions Recommended tightening torque 30 Ncm for the screw.
    Additional parts Metal cap (Ref: C116)
    Laboratory (Ref: C117)
    Extra soft (Ref: C118)
    Soft (Ref: C119)
    Standard (Ref: C120)
    Strong (Ref: C121)
    Protective disk (Ref: C122)
    Accessories T1 – S35 Transfer (Ref: C114)
    A1 – S35 Analog (Ref: C115)
    K21 Hand tool (Ref: B21)
  • S35 – S7 – 3.75, 17°

    0.00

    Overdenture S-Lock angular abutments – 17°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32171/C113)
    2mm (Ref: M32172/C113)
    3mm (Ref: M32173/C113)
    Instructions Recommended tightening torque 30 Ncm for the screw.
    Additional parts Metal cap (Ref: C116)
    Laboratory (Ref: C117)
    Extra soft (Ref: C118)
    Soft (Ref: C119)
    Standard (Ref: C120)
    Strong (Ref: C121)
    Protective disk (Ref: C122)
    Accessories T1 – S35 Transfer (Ref: C114)
    A1 – S35 Analog (Ref: C115)
    K21 Hand tool (Ref: B21)
  • S35 – S7 – 3.75, 30°

    0.00

    Overdenture S-Lock angular abutments – 30°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32171/C113)
    2mm (Ref: M32172/C113)
    3mm (Ref: M32173/C113)
    Instructions Recommended tightening torque 30 Ncm for the screw.
    Additional parts Metal cap (Ref: C116)
    Laboratory (Ref: C117)
    Extra soft (Ref: C118)
    Soft (Ref: C119)
    Standard (Ref: C120)
    Strong (Ref: C121)
    Protective disk (Ref: C122)
    Accessories T1 – S35 Transfer (Ref: C114)
    A1 – S35 Analog (Ref: C115)
    K21 Hand tool (Ref: B21)
  • S5 – 3.75

    0.00

    Overdenture Easy-Fix abutments.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M571)
    2mm (Ref: M572)
    3mm (Ref: M573)
    4mm (Ref: M574)
    5mm (Ref: M575)
    6mm (Ref: M576)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts Metal cap (Ref: C50)
    Laboratory (Ref: C54)
    Medium (Ref: C52)
    Accessories T1 – S5 Transfer (Ref: C58)
    A1 – S5 Analog (Ref: C59)
  • S5 – S7 – 3.75, 17°

    0.00

    Overdenture Easy-Fix angular abutments – 17°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32171/C441)
    2mm (Ref: M32172/C441)
    3mm (Ref: M32173/C441)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts Metal cap (Ref: C50)
    Laboratory (Ref: C54)
    Hard (Ref: C51b)
    Soft (Ref: C53)
    Accessories T1 – S5 Transfer (Ref: C58)
    A1 – S5 Analog (Ref: C59)
    1mm (Ref: C441)  / 2mm (Ref: C442)

     

  • S5 – S7 – 3.75, 30°

    0.00

    Overdenture Easy-Fix angular abutments – 30°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M32301/C441)
    2mm (Ref: M32302/C441)
    3mm (Ref: M32303/C441)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional parts Metal cap (Ref: C50)
    Laboratory (Ref: C54)
    Hard (Ref: C51b)
    Soft (Ref: C53)
    Accessories T1 – S5 Transfer (Ref: C58)
    A1 – S5 Analog (Ref: C59)
    1mm (Ref: C441)  / 2mm (Ref: C442)