Showing 1–9 of 42 results

  • S1 – 3.75

    0.00

    Straight titanium abutment with hex.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 5mm (Ref: M115)
    7mm (Ref: M117)
    9mm (Ref: M119)
    12mm (Ref: M1112)
    15mm (Ref: M1115)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional info Two screws included*

    *Blue screw for the final restoration, silver screw is suitable for the laboratory.

  • S16 – 3.75

    0.00

    The One multi-unit abutments.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M641)
    2mm (Ref: M642)
    3mm (Ref: M643)
    4mm (Ref: M644)
    5mm (Ref: M645)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Accessories T3 – S16/S17 Closed tray transfer (Ref: C72)
    T1 – S16/S17 Open tray transfer (Ref: C67)
    A1 – S16/S17 Analog (Ref: C68)
    H – S16/S17 Healing cap (Ref: C66)
    P – S16/S17 plastic (Ref: C71)  
    P – S16/S17 plastic (Ref: C85)  
    TW – S16/S17 (Ref: C73)
    T – S16/S17 (Ref: C69)

     

  • S17 – 3.75, 17°

    0.00

    The One multi-unit angular abutments – 17°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M65171)
    2mm (Ref: M65172)
    3mm (Ref: M65173)
    4mm (Ref: M65174)
    5mm (Ref: M65175)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Accessories T3 – S16/S17 Closed tray transfer (Ref: C72)
    T1 – S16/S17 Open tray transfer (Ref: C67)
    A1 – S16/S17 Analog (Ref: C68)
    H – S16/S17 Healing cap (Ref: C66)
    P – S16/S17 plastic (Ref: C71)  
    P – S16/S17 plastic (Ref: C85)  
    TW – S16/S17 (Ref: C73)
    T – S16/S17 (Ref: C69)

     

  • S17 – 3.75, 30°

    0.00

    The One multi-unit angular abutments – 30°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M65301)
    2mm (Ref: M65302)
    3mm (Ref: M65303)
    4mm (Ref: M65304)
    5mm (Ref: M65305)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Accessories T3 – S16/S17 Closed tray transfer (Ref: C72)
    T1 – S16/S17 Open tray transfer (Ref: C67)
    A1 – S16/S17 Analog (Ref: C68)
    H – S16/S17 Healing cap (Ref: C66)
    P – S16/S17 plastic (Ref: C71)  
    P – S16/S17 plastic (Ref: C85)  
    TW – S16/S17 (Ref: C73)
    T – S16/S17 (Ref: C69)
  • S17 – 3.75, 45°

    0.00

    The One multi-unit angular abutments – 45°.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M65451)
    2mm (Ref: M65452)
    3mm (Ref: M65453)
    4mm (Ref: M65454)
    5mm (Ref: M65455)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Accessories T3 – S16/S17 Closed tray transfer (Ref: C72)
    T1 – S16/S17 Open tray transfer (Ref: C67)
    A1 – S16/S17 Analog (Ref: C68)
    H – S16/S17 Healing cap (Ref: C66)
    P – S16/S17 plastic (Ref: C71)  
    P – S16/S17 plastic (Ref: C85)  
    TW – S16/S17 (Ref: C73)
    T – S16/S17 (Ref: C69)
  • S1A – 3.75

    0.00

    Anatomic straight titanium abutment with hex.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 1mm (Ref: M121)
    2mm (Ref: M122)
    3mm (Ref: M123)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional info Two screws included*

    *Blue screw for the final restoration, silver screw is suitable for the laboratory.

  • S1A – Peek – 3.75

    0.00

    Peek temporary abutment.

    Connection Type Internal Hex (Platform 3.75)
    Material Peek-Classix polymer
    Available sizes 1mm (Ref: M181)
    2mm (Ref: M182)
    3mm (Ref: M183)
    Instructions Recommended tightening torque 15 Ncm for the screw.
    The peek abutments can be used for maximum 1 year.
    Additional info Screw included
  • S1AZT – 3.75

    0.00

    Anatomic zirconium abutment with titanium base.

    Connection Type Internal Hex (Platform 3.75)
    Material Zirconium / Titanium
    Available sizes 1mm (Ref: M161T)
    2mm (Ref: M162T)
    3mm (Ref: M163T)
    Instructions Recommended tightening torque 25  Ncm for the screw.
    Additional info Screw included

     

  • S1N – 3.75

    0.00

    Straight narrow titanium abutment with hex.

    Connection Type Internal Hex (Platform 3.75)
    Material Titanium
    Available sizes 7mm (Ref: M11N7)
    9mm (Ref: M11N9)
    Instructions Recommended tightening torque 25 Ncm for the screw.
    Additional info Two screws included*

    *Blue screw for the final restoration, silver screw is suitable for the laboratory.