A1 – 3.75
₹0.00Analog.
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Stainless steel |
| Available sizes | 12mm (Ref: M08) |
| Instructions | Suitable for all diameters of P1/P7. |
| Additional info |
Showing 1–9 of 57 results

Analog.
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Stainless steel |
| Available sizes | 12mm (Ref: M08) |
| Instructions | Suitable for all diameters of P1/P7. |
| Additional info |

Healing cap.
Diameter: 4,7mm
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 2mm (Ref: M10472) 3mm (Ref: M10473) 4mm (Ref: M10474) 5mm (Ref: M10475) 6mm (Ref: M10476) |
| Instructions | Suitable for all implant diameters. Recommended tightening torque 15 Ncm for the screw. |
| Additional info | – |

Narrow healing cap.
Diameter: 3,8 mm
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 3mm (Ref: M10383) 5mm (Ref: M10385) |
| Instructions | Suitable for all implant diameters. Recommended tightening torque 25 Ncm for the screw. |
| Additional info | – |

Wide healing cap.
Diameter: 5,8 mm
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 3mm (Ref: M10583) 5mm (Ref: M10585) |
| Instructions | Suitable for all implant diameters. Recommended tightening torque 25 Ncm for the screw. |
| Additional info | – |

Wide healing cap.
Diameter: 7,0 mm
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 3mm (Ref: M10703) 5mm (Ref: M10705) |
| Instructions | Suitable for all implant diameters. Recommended tightening torque 25 Ncm for the screw. |
| Additional info | – |

Wide healing cap.
Diameter: 8,0 mm
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 3mm (Ref: M10803) 5mm (Ref: M10805) |
| Instructions | Suitable for all implant diameters. Recommended tightening torque 25 Ncm for the screw. |
| Additional info | – |

Straight titanium abutment with hex.
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 5mm (Ref: M115) 7mm (Ref: M117) 9mm (Ref: M119) 12mm (Ref: M1112) 15mm (Ref: M1115) |
| Instructions | Recommended tightening torque 25 Ncm for the screw. |
| Additional info | Two screws included* |
*Blue screw for the final restoration, silver screw is suitable for the laboratory.

| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 1mm (Ref: M641) 2mm (Ref: M642) 3mm (Ref: M643) 4mm (Ref: M644) 5mm (Ref: M645) |
| Instructions | Recommended tightening torque 25 Ncm for the screw. |
| Accessories | T3 – S16/S17 Closed tray transfer (Ref: C72) T1 – S16/S17 Open tray transfer (Ref: C67) A1 – S16/S17 Analog (Ref: C68) H – S16/S17 Healing cap (Ref: C66) P – S16/S17 plastic (Ref: C71)  P – S16/S17 plastic (Ref: C85)  TW – S16/S17 (Ref: C73) T – S16/S17 (Ref: C69) |

The One multi-unit angular abutments – 17°.
| Connection Type | Internal Hex (Platform 3.75) |
| Material | Titanium |
| Available sizes | 1mm (Ref: M65171) 2mm (Ref: M65172) 3mm (Ref: M65173) 4mm (Ref: M65174) 5mm (Ref: M65175) |
| Instructions | Recommended tightening torque 25 Ncm for the screw. |
| Accessories | T3 – S16/S17 Closed tray transfer (Ref: C72) T1 – S16/S17 Open tray transfer (Ref: C67) A1 – S16/S17 Analog (Ref: C68) H – S16/S17 Healing cap (Ref: C66) P – S16/S17 plastic (Ref: C71)  P – S16/S17 plastic (Ref: C85)  TW – S16/S17 (Ref: C73) T – S16/S17 (Ref: C69) |